TDS Meter Converter

–ppm TDS
–verdict
–RO membrane check
–grains equivalent
WaterµS/cmTDS ppm (x0.64)
RO filtered10-506-32
Distilled0.5-50-3
Typical tap150-40096-256
Well water (mineral-rich)500-1500320-960
Seawater~50,000~32,000
A TDS meter does not weigh dissolved solids - it measures how well the water conducts electricity and multiplies by a factor. 0.64 suits sodium-chloride-dominant water (most US meters); Europe commonly uses 0.5 - so the same water reads differently on different meters, and the factor is the reason.
The number that matters for drinking water: WHO guidance discusses taste and treatment rather than a hard TDS limit - palatability degrades somewhere past 600-1000 ppm. The reference: WHO: Drinking-water. The scale side of the same tap: water hardness units.

A TDS meter never weighs the solids in your water - it measures electrical conductivity and multiplies by a factor that guesses the mix. US meters use 0.64 (sodium-chloride calibration), European practice often 0.5, some analog dials 0.7 - which is why the same glass of water reads three different ppm values on three meters.

Bottom line: 300 uS/cm x 0.64 = 192 ppm TDS - typical treated tap water; reverse-osmosis output should read under 50 uS/cm (32 ppm), and a reading creeping toward 10 percent of the feed means the membrane is done.

The number everyone actually wants: palatability. WHO guidance discusses drinking-water treatment rather than a hard TDS ceiling, but taste falls off somewhere past 600-1000 ppm - brackish wells and seawater desalination feeds live well beyond it.

How to use

  1. Type the uS/cm conductivity your meter shows.
  2. Pick the factor your meter brand uses - or test all three.
  3. Check the verdict: RO-grade, typical tap, or past the taste line.

Frequently asked questions

What factor does my TDS meter use?

Most US-sold meters use 0.64 (NaCl calibration); many European meters 0.5; some analog meters 0.7. The manual states it - and if two meters disagree on the same water, the factor is almost always the reason rather than a fault.

What TDS should reverse osmosis water read?

A healthy RO membrane rejects 90-98 percent of dissolved solids: output under 50 uS/cm (roughly 30 ppm) is normal. When output climbs toward a tenth of the incoming reading, the membrane or its prefilters are spent.

Is high TDS unsafe?

Not by itself - TDS is a total, not an identity. Lead at dangerous levels barely moves a TDS meter, while harmless calcium moves it a lot. Use TDS for treatment performance (RO, filters) and send specific-ion questions to a lab test, not a meter.

What is a good TDS for coffee and tea?

The Specialty Coffee Association targets about 75-150 ppm - enough minerals to carry flavor, few enough not to fight extraction. Distilled (<10 ppm) brews flat; hard tap water (>300 ppm) mutes acidity and scales the machine.

Related tools